We didn't use interactive service when gui was running
under admin because of some privilege escalation vulnerability in Vista.
Apparently this issue doesn't exist on Win7 and newer versions so
it is safe to use iservice on those systems.
Introduce "Always use interactive service" option,
which is "on" by default. This should enable users,
who by various reasons run gui as admin, use Wintun.
When gui is running as admin and interactive service
cannot be started or not installed, warn that wintun will not work.
Signed-off-by: Lev Stipakov <lev@openvpn.net>
- Prompt the user for permission if import may overwrite
an existing config.
- Also raise an error if the import file source matches the
global or local config directory. Reimporting a config on to
itself is not supported. This also avoids ERROR_SHARING_VIOLATION
in CopyFile() when source and destination are the same.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- This checkbox is inactive and does nothing.
The service-only usage can be still activated using the command
line option --service_only or by editing the registry, but its
not a recommended use case for GUI version 11.0 and above.
See also issue: #264
Signed-off-by: Selva Nair <selva.nair@gmail.com>
After a failure the auth-pass dialog is shown with the password
field prefilled but highlighted. This allows the user to easily
overwrite the password or resubmit the old password if the
failure was temporary.
After a private key passphrase failure, the dialog is not
prefilled with saved password as this failure happens locally
and in such cases the password is very likely wrong.
If the user aborts the dialog by pressing cancel, the saved
password will get used during the next connection attempt.
Wrong username or password warning text is changed to: "Wrong
credentials".
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Show the assigned IP numbers, traffic stats (bytes in/out), and
the GUI and OpenVPN core versions on the status window.
Note: IDS_TXT_BYTECOUNT = "Bytes in: %s out %s" needs translation.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
Why: The current message assumes the balloon to appear attached
to the icon which is not the case in Windows 10.
Based on feedback from larson0815 and Deantwo here:
https://github.com/selvanair/openvpn-gui/issues/5
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- New option --command <action> <params> to send commands to
a running instance of openvpn-gui.exe
Supported actions are
connect, disconnect, reconnect
each of which takes the name of the config (with or without the
extension .ovpn) as a parameter;
disconnect_all, exit
which take no parameter and
silent_connection
which takes an optional parameter = 0 or 1 (1 is the default)
Examples: with the gui running, start a new instance as
openvpn-gui.exe --command disconnect myvpn : ask running instance
to disconnect myvpn if connected
openvpn-gui.exe --command status myvpn : ask running instance
to show the status window for myvpn if available
openvpn-gui.exe --command disconnect_all : ask running instance
to disconnect all active connections
- The second instance exits after issuing a SendMessage to the
already running instance. If no action is specified, the running
instance is notified to show a balloon to alert the user
- These messages may also be sent from scripts as COPYDATA messages
with the wData element specifying the action to execute and lpData
a pointer to the parameter. The dwData param must be one of
WM_OVPN_xxx with xxx = START, STOP, RESTART, STOPALL, EXIT or
SILENT. See main.h for their values.
v2: Bug fixes based on test reports from larson0815
here: https://github.com/selvanair/openvpn-gui/issues/5
and cron410 here: https://github.com/OpenVPN/openvpn-gui/issues/104
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- This works the same way as restart button in the status window
but is more conveniently accessible from the tray menu.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Effective only when username and password are saved.
- The user may interrupt auto submission and edit the username/password.
- If silent_connection is on the dialog is bypassed without any delay.
v2 changes:
- Display message in normal text color and show remaining time
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Make the OK button appear highlighted as the default action so that
the user can press enter and submit the form. This also gives a clearer
indication of the default action when automatic submission of saved
username/password activates.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Flag password and username input if these contain an invalid character
(currently only embedded '\n' is disallowed). Shows a popup when OK
is pressed so that the user can correct the input and resubmit.
- Add an error message to the log when the management i/f returns
ERROR for incorrectly parsed commands. Otherwise such errors go
unnoticed.
Note: IDS_ERR_INVALID_USERNAME/PASSWORD need translations.
Reported and tested by: Florian Beier (H4ndl3 on github)
Fixes Trac: #958
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- "Wrong username or password" message shown in the auth userpass dialog after
an auth failure
- "Wrong password" message shown in the private key password dialog after a
password failure.
These message texts are colored red by default (TODO: make the color customizable)
Signed-off-by: Selva Nair <selva.nair@gmail.com>
Without this the service will continue to wait for input from GUI
and log pipe read errors to the event log.
Also fix a typo in the error messgae shown.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
Warnings dsabled if silent_connection is true
- interactive service is not installed or not running
- duplicate configs found and ignored
v2: Update description of --silent_connection in README
and English resource file (translations not updated).
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Copy updates to copyright by commit 32c31ab942 in
Englishc to all other language files.
- Change version displayed in About page to the form
"a.b.c.d"
- General settings dialog is incomplete in chinese:
copy from English version.
- Add the word "OpenVPN" in the About page of Norwegian
mistakenly removed by commit d81b93d487..
Signed-off-by: Selva Nair <selva.nair@gmail.com>
Note: IDS_NFO_TOKEN_PASSWORD_CAPTION and IDS_NFO_TOKEN_PASSWORD_REQUEST
strings need translation.
TODO: support for selecting pkcs11-id from the GUI
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Add a base64 decode function using Windows CyptoAPI
- Move multibyte to widechar conversions to a function
- Add config name to caption of password dialogs to help user
identify the request
- Add new dialog template for generic password/PIN requests
and use it to handle dynamic challenge
Note 1: if dynamic challenge response verification fails, an auth-failed
message is returned by the server causing the GUI to clear any saved
password even if the user-auth dialog itself succeeeded.
Note 2: Dialog template ID_DLG_CHALLENGE_RESPONSE added to language
files may require translation.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
Option ediitng dialogs are in two tabs: General and Advanced.
Proxy related options are left in the proxy tab. Options
config_dir, config_ext, log_dir, script timeouts and
service-only flag are in the Advanced tab. All other more commonly
used flags and options are in the General tab.
- As options are editable, save values in registry only when they differ
from the default values. This leaves the registry clean and makes changing
options and their defaults during updates easier.
- Entries for config_dir and log_dir must be absolute paths.
Environemental variables such as %PROFILEDIR% may be used
to construct these.
- Empty config_dir, config_ext and log_dir entries are silently
ignored (i.e., the current values are left unchanged).
- Store all numeric and boolean parameters in registry as DWORD instead of
strings.
- On startup, the default parameters are loaded, then the registry is read
and finally command-line parameters parsedi.
- Out of range script timeout values in registry truncated with a
warning instead of fatal error. This allows the user to access the
settings dialog and make corrections.
- Save proxy and language settings under the same
HKCU\Software\OpenVPN-GUI key as other options instead of under Nilings.
- Save the current version of the GUI in regsitry so that updates
can be detected and any needed registry cleanup done.
- If no version info is present in the registry any values in OpenVPN-GUI
key in HKCU are deleted for a clean start as this is the first version
to save registry values in HKCU. Language and proxy data if present
under Nilings is migrated.
Note: new controls in the General tab and newly added Advanced tab dialog
are copied to all language files from the English version. These need to
be translated.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Replace allow_password by a runtime check that enables password
change menu only when the user has write-access to the key file.
- Read exe_path and priority from HKLM and do not duplicate in HKCU.
- Always allow the user to view the config: edit will succeed if user
has write access.
- Always include the proxy settings tab which is the default.
- Remove the unused power event handling and disconnect_on_suspend key.
- Remove password_attempts -- user can stop the password dilaog
by clicking cancel.
- Remove allow_service: implicitly enabled if service_only is used.
- Deprecate removed options in cmd-line parser
- Update README.rst
- Close config file before exit in GetKeyFileName
- Close thread and dialog handles in passphrase.c
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Username and, optionally, password as well as the private
key passphrase are saved in config-specific registry keys
- All saved data are kept encrypted using DPAPI
- The passphrase dialog is skipped if a valid saved private
key password is available. However, the user-auth dialog
is always presented, prefilled with the saved username
and password.
Note: A text string "Save password" is added to three dialogs
in all language resource files. Additional text with ids
IDS_MENU_CLEARPASS and IDS_NFO_DELETE_PASS are added to the
STRINGTABLE only in the English language resource file.
All these need translations.
Signed-off-by: Selva Nair <selva.nair@gmail.com>
When a connection is attempted using a config in a location
that would fail, offer an option to add the user to the "OpenVPN
Administrators" group. This is done using shell-execute which will
show a UAC prompt for elevation. If it fails (due to user chooses
NO or the UAC dialog fails) the connection is not started.
v2 Changes
- Rebase to master
- Automaticlaly add the admin group if it doesn't exist
- Allow unicode strings in debug output
- Use domain\username to identify user
- Fix the PrintDebug macro
Minor changes based on user feedback
- Bring the window back to foreground after UAC prompt completion
- Show a message if another connection is tried during authorization
- Do not add user to ovpn_admin_group if it is same as the built-in admin group
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Set default config directory (config_dir) to %UserProfile%\OpenVPN\config
(saved and read back from HKCU\Software\OpenVPN-GUI\config_dir)
- Add a global_config_dir variable read from HKLM\Software\OpenVPN\config_dir
or set to OpenVPN-install-path\config
- Scan both directories and their sub directories for connection profiles.
In case of name conflicts config_dir gets priority over global_config_dir
- Eliminate multiple warnings of duplicate configs
Fixed on review (Thanks to leobasilio@gmail.com)
- Fix wrongly used o.config_dir in 2 locations
- Unrelated: Added missing CheckIServiceStatus to service.h
Signed-off-by: Selva Nair <selva.nair@gmail.com>
- Handle early errors (openvpn exits before management connection is up)
with a helpful error message that points the user to view log.
- Include only readable config files in the connection list
- Warn if no connection profiles found
TODO: handle startup errors from interactive service
Change the default log file location to OpenVPN/log in user's profile directory
to support running without admin privileges using the interactive service.
The registry keys are moved to HKCU from HKLM to allow for user-specific
settings as well as to avoid the need for running the GUI as admin at the
first instance.
Signed-off-by: Selva Nair <selva.nair@gmail.com>