Browse Source

Merge pull request #14129 from prometheus/beorn7/doc

doc: Clarify the limits of dumping/backfilling via OpenMetrics
pull/12339/head^2
Björn Rabenstein 6 months ago committed by GitHub
parent
commit
1081e336a0
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
  1. 2
      cmd/promtool/main.go
  2. 2
      docs/command-line/promtool.md
  3. 3
      docs/storage.md

2
cmd/promtool/main.go

@ -240,7 +240,7 @@ func main() {
dumpMaxTime := tsdbDumpCmd.Flag("max-time", "Maximum timestamp to dump.").Default(strconv.FormatInt(math.MaxInt64, 10)).Int64()
dumpMatch := tsdbDumpCmd.Flag("match", "Series selector. Can be specified multiple times.").Default("{__name__=~'(?s:.*)'}").Strings()
tsdbDumpOpenMetricsCmd := tsdbCmd.Command("dump-openmetrics", "[Experimental] Dump samples from a TSDB into OpenMetrics format. Native histograms are not dumped.")
tsdbDumpOpenMetricsCmd := tsdbCmd.Command("dump-openmetrics", "[Experimental] Dump samples from a TSDB into OpenMetrics text format, excluding native histograms and staleness markers, which are not representable in OpenMetrics.")
dumpOpenMetricsPath := tsdbDumpOpenMetricsCmd.Arg("db path", "Database path (default is "+defaultDBPath+").").Default(defaultDBPath).String()
dumpOpenMetricsSandboxDirRoot := tsdbDumpOpenMetricsCmd.Flag("sandbox-dir-root", "Root directory where a sandbox directory would be created in case WAL replay generates chunks. The sandbox directory is cleaned up at the end.").Default(defaultDBPath).String()
dumpOpenMetricsMinTime := tsdbDumpOpenMetricsCmd.Flag("min-time", "Minimum timestamp to dump.").Default(strconv.FormatInt(math.MinInt64, 10)).Int64()

2
docs/command-line/promtool.md

@ -585,7 +585,7 @@ Dump samples from a TSDB.
##### `promtool tsdb dump-openmetrics`
[Experimental] Dump samples from a TSDB into OpenMetrics format. Native histograms are not dumped.
[Experimental] Dump samples from a TSDB into OpenMetrics text format, excluding native histograms and staleness markers, which are not representable in OpenMetrics.

3
docs/storage.md

@ -197,6 +197,9 @@ or time-series database to Prometheus. To do so, the user must first convert the
source data into [OpenMetrics](https://openmetrics.io/) format, which is the
input format for the backfilling as described below.
Note that native histograms and staleness markers are not supported by this
procedure, as they cannot be represented in the OpenMetrics format.
### Usage
Backfilling can be used via the Promtool command line. Promtool will write the blocks

Loading…
Cancel
Save