Issue #218 - ProcessHelper#StartProcessAndCallbackForExit() should redirect STDOUT/STDERR when LogHandler is defined
It restores logging of executables, which has been broken in https://github.com/kohsuke/winsw/pull/220. Not a regression, because the change has not been released yetpull/224/head
parent
cfacfe3879
commit
05092376f3
|
@ -136,7 +136,8 @@ namespace winsw
|
|||
/// <summary>
|
||||
/// Handle the creation of the logfiles based on the optional logmode setting.
|
||||
/// </summary>
|
||||
private void HandleLogfiles()
|
||||
/// <returns>Log Handler, which should be used for the spawned process</returns>
|
||||
private LogHandler CreateExecutableLogHandler()
|
||||
{
|
||||
string logDirectory = _descriptor.LogDirectory;
|
||||
|
||||
|
@ -147,7 +148,7 @@ namespace winsw
|
|||
|
||||
LogHandler logAppender = _descriptor.LogHandler;
|
||||
logAppender.EventLogger = this;
|
||||
logAppender.log(_process.StandardOutput.BaseStream, _process.StandardError.BaseStream);
|
||||
return logAppender;
|
||||
}
|
||||
|
||||
public void LogEvent(String message)
|
||||
|
@ -247,12 +248,10 @@ namespace winsw
|
|||
LogEvent("Starting " + _descriptor.Executable + ' ' + startarguments);
|
||||
Log.Info("Starting " + _descriptor.Executable + ' ' + startarguments);
|
||||
|
||||
StartProcess(_process, startarguments, _descriptor.Executable);
|
||||
LogHandler executableLogHandler = CreateExecutableLogHandler();
|
||||
StartProcess(_process, startarguments, _descriptor.Executable, executableLogHandler);
|
||||
ExtensionManager.FireOnProcessStarted(_process);
|
||||
|
||||
// send stdout and stderr to its respective output file.
|
||||
HandleLogfiles();
|
||||
|
||||
_process.StandardInput.Close(); // nothing for you to read!
|
||||
}
|
||||
|
||||
|
@ -322,7 +321,8 @@ namespace winsw
|
|||
executable = _descriptor.Executable;
|
||||
}
|
||||
|
||||
StartProcess(stopProcess, stoparguments, executable);
|
||||
// TODO: Redirect logging to Log4Net once https://github.com/kohsuke/winsw/pull/213 is integrated
|
||||
StartProcess(stopProcess, stoparguments, executable, null);
|
||||
|
||||
Log.Debug("WaitForProcessToExit " + _process.Id + "+" + stopProcess.Id);
|
||||
WaitForProcessToExit(_process);
|
||||
|
@ -407,7 +407,7 @@ namespace winsw
|
|||
Advapi32.SetServiceStatus(handle, ref _wrapperServiceStatus);
|
||||
}
|
||||
|
||||
private void StartProcess(Process processToStart, string arguments, String executable)
|
||||
private void StartProcess(Process processToStart, string arguments, String executable, LogHandler logHandler)
|
||||
{
|
||||
|
||||
// Define handler of the completed process
|
||||
|
@ -454,7 +454,8 @@ namespace winsw
|
|||
envVars: _envs,
|
||||
workingDirectory: _descriptor.WorkingDirectory,
|
||||
priority: _descriptor.Priority,
|
||||
callback: processCompletionCallback);
|
||||
callback: processCompletionCallback,
|
||||
logHandler: logHandler);
|
||||
}
|
||||
|
||||
public static int Main(string[] args)
|
||||
|
|
|
@ -129,8 +129,9 @@ namespace winsw.Util
|
|||
/// <param name="workingDirectory">Working directory</param>
|
||||
/// <param name="priority">Priority</param>
|
||||
/// <param name="callback">Completion callback. If null, the completion won't be monitored</param>
|
||||
/// <param name="logHandler">Log handler. If enabled, logs will be redirected to the process and then reported</param>
|
||||
public static void StartProcessAndCallbackForExit(Process processToStart, String executable = null, string arguments = null, Dictionary<string, string> envVars = null,
|
||||
string workingDirectory = null, ProcessPriorityClass? priority = null, ProcessCompletionCallback callback = null)
|
||||
string workingDirectory = null, ProcessPriorityClass? priority = null, ProcessCompletionCallback callback = null, LogHandler logHandler = null)
|
||||
{
|
||||
var ps = processToStart.StartInfo;
|
||||
ps.FileName = executable ?? ps.FileName;
|
||||
|
@ -138,9 +139,9 @@ namespace winsw.Util
|
|||
ps.WorkingDirectory = workingDirectory ?? ps.WorkingDirectory;
|
||||
ps.CreateNoWindow = false;
|
||||
ps.UseShellExecute = false;
|
||||
ps.RedirectStandardInput = false;
|
||||
ps.RedirectStandardOutput = false;
|
||||
ps.RedirectStandardError = false;
|
||||
ps.RedirectStandardInput = false;
|
||||
ps.RedirectStandardOutput = logHandler != null;
|
||||
ps.RedirectStandardError = logHandler != null;
|
||||
|
||||
if (envVars != null)
|
||||
{
|
||||
|
@ -160,6 +161,13 @@ namespace winsw.Util
|
|||
processToStart.PriorityClass = priority.Value;
|
||||
}
|
||||
|
||||
// Redirect logs if required
|
||||
if (logHandler != null)
|
||||
{
|
||||
Logger.Debug("Forwarding logs of the process " + processToStart + " to " + logHandler);
|
||||
logHandler.log(processToStart.StandardOutput.BaseStream, processToStart.StandardError.BaseStream);
|
||||
}
|
||||
|
||||
// monitor the completion of the process
|
||||
if (callback != null)
|
||||
{
|
||||
|
|