prometheusmetricshost-metricsmachine-metricsnode-metricsprocfsprometheus-exportersystem-informationsystem-metrics
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
205 lines
7.2 KiB
205 lines
7.2 KiB
// Copyright 2015 The Prometheus Authors |
|
// Licensed under the Apache License, Version 2.0 (the "License"); |
|
// you may not use this file except in compliance with the License. |
|
// You may obtain a copy of the License at |
|
// |
|
// http://www.apache.org/licenses/LICENSE-2.0 |
|
// |
|
// Unless required by applicable law or agreed to in writing, software |
|
// distributed under the License is distributed on an "AS IS" BASIS, |
|
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
|
// See the License for the specific language governing permissions and |
|
// limitations under the License. |
|
|
|
// +build !nocpu |
|
|
|
package collector |
|
|
|
import ( |
|
"fmt" |
|
"io/ioutil" |
|
"os" |
|
"path/filepath" |
|
"regexp" |
|
"strings" |
|
|
|
"github.com/prometheus/client_golang/prometheus" |
|
"github.com/prometheus/common/log" |
|
"github.com/prometheus/procfs" |
|
) |
|
|
|
const ( |
|
cpuCollectorSubsystem = "cpu" |
|
) |
|
|
|
var ( |
|
digitRegexp = regexp.MustCompile("[0-9]+") |
|
) |
|
|
|
type cpuCollector struct { |
|
cpu *prometheus.Desc |
|
cpuFreq *prometheus.Desc |
|
cpuFreqMin *prometheus.Desc |
|
cpuFreqMax *prometheus.Desc |
|
cpuCoreThrottle *prometheus.Desc |
|
cpuPackageThrottle *prometheus.Desc |
|
} |
|
|
|
func init() { |
|
registerCollector("cpu", defaultEnabled, NewCPUCollector) |
|
} |
|
|
|
// NewCPUCollector returns a new Collector exposing kernel/system statistics. |
|
func NewCPUCollector() (Collector, error) { |
|
return &cpuCollector{ |
|
cpu: prometheus.NewDesc( |
|
prometheus.BuildFQName(namespace, "", cpuCollectorSubsystem), |
|
"Seconds the cpus spent in each mode.", |
|
[]string{"cpu", "mode"}, nil, |
|
), |
|
cpuFreq: prometheus.NewDesc( |
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "frequency_hertz"), |
|
"Current cpu thread frequency in hertz.", |
|
[]string{"cpu"}, nil, |
|
), |
|
cpuFreqMin: prometheus.NewDesc( |
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "frequency_min_hertz"), |
|
"Minimum cpu thread frequency in hertz.", |
|
[]string{"cpu"}, nil, |
|
), |
|
cpuFreqMax: prometheus.NewDesc( |
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "frequency_max_hertz"), |
|
"Maximum cpu thread frequency in hertz.", |
|
[]string{"cpu"}, nil, |
|
), |
|
// FIXME: This should be a per core metric, not per cpu! |
|
cpuCoreThrottle: prometheus.NewDesc( |
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "core_throttles_total"), |
|
"Number of times this cpu core has been throttled.", |
|
[]string{"cpu"}, nil, |
|
), |
|
cpuPackageThrottle: prometheus.NewDesc( |
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "package_throttles_total"), |
|
"Number of times this cpu package has been throttled.", |
|
[]string{"node"}, nil, |
|
), |
|
}, nil |
|
} |
|
|
|
// Update implements Collector and exposes cpu related metrics from /proc/stat and /sys/.../cpu/. |
|
func (c *cpuCollector) Update(ch chan<- prometheus.Metric) error { |
|
if err := c.updateStat(ch); err != nil { |
|
return err |
|
} |
|
if err := c.updateCPUfreq(ch); err != nil { |
|
return err |
|
} |
|
return nil |
|
} |
|
|
|
// updateCPUfreq reads /sys/bus/cpu/devices/cpu* and expose cpu frequency statistics. |
|
func (c *cpuCollector) updateCPUfreq(ch chan<- prometheus.Metric) error { |
|
cpus, err := filepath.Glob(sysFilePath("bus/cpu/devices/cpu[0-9]*")) |
|
if err != nil { |
|
return err |
|
} |
|
|
|
var value uint64 |
|
|
|
// cpu loop |
|
for _, cpu := range cpus { |
|
_, cpuname := filepath.Split(cpu) |
|
|
|
if _, err := os.Stat(filepath.Join(cpu, "cpufreq")); os.IsNotExist(err) { |
|
log.Debugf("CPU %q is missing cpufreq", cpu) |
|
} else { |
|
// sysfs cpufreq values are kHz, thus multiply by 1000 to export base units (hz). |
|
// See https://www.kernel.org/doc/Documentation/cpu-freq/user-guide.txt |
|
if value, err = readUintFromFile(filepath.Join(cpu, "cpufreq", "scaling_cur_freq")); err != nil { |
|
return err |
|
} |
|
ch <- prometheus.MustNewConstMetric(c.cpuFreq, prometheus.GaugeValue, float64(value)*1000.0, cpuname) |
|
|
|
if value, err = readUintFromFile(filepath.Join(cpu, "cpufreq", "scaling_min_freq")); err != nil { |
|
return err |
|
} |
|
ch <- prometheus.MustNewConstMetric(c.cpuFreqMin, prometheus.GaugeValue, float64(value)*1000.0, cpuname) |
|
|
|
if value, err = readUintFromFile(filepath.Join(cpu, "cpufreq", "scaling_max_freq")); err != nil { |
|
return err |
|
} |
|
ch <- prometheus.MustNewConstMetric(c.cpuFreqMax, prometheus.GaugeValue, float64(value)*1000.0, cpuname) |
|
} |
|
|
|
if _, err := os.Stat(filepath.Join(cpu, "thermal_throttle")); os.IsNotExist(err) { |
|
log.Debugf("CPU %q is missing thermal_throttle", cpu) |
|
continue |
|
} |
|
if value, err = readUintFromFile(filepath.Join(cpu, "thermal_throttle", "core_throttle_count")); err != nil { |
|
return err |
|
} |
|
ch <- prometheus.MustNewConstMetric(c.cpuCoreThrottle, prometheus.CounterValue, float64(value), cpuname) |
|
} |
|
|
|
pkgs, err := filepath.Glob(sysFilePath("bus/node/devices/node[0-9]*")) |
|
if err != nil { |
|
return err |
|
} |
|
|
|
// package/node loop |
|
for _, pkg := range pkgs { |
|
if _, err := os.Stat(filepath.Join(pkg, "cpulist")); os.IsNotExist(err) { |
|
log.Debugf("package %q is missing cpulist", pkg) |
|
continue |
|
} |
|
cpulist, err := ioutil.ReadFile(filepath.Join(pkg, "cpulist")) |
|
if err != nil { |
|
log.Debugf("could not read cpulist of package %q", pkg) |
|
return err |
|
} |
|
// cpulist example of one package/node with HT: "0-11,24-35" |
|
line := strings.Split(string(cpulist), "\n")[0] |
|
firstCPU := strings.FieldsFunc(line, func(r rune) bool { |
|
return r == '-' || r == ',' |
|
})[0] |
|
if _, err := os.Stat(filepath.Join(pkg, "cpu"+firstCPU, "thermal_throttle", "package_throttle_count")); os.IsNotExist(err) { |
|
log.Debugf("Package %q CPU %q is missing package_throttle", pkg, firstCPU) |
|
continue |
|
} |
|
if value, err = readUintFromFile(filepath.Join(pkg, "cpu"+firstCPU, "thermal_throttle", "package_throttle_count")); err != nil { |
|
return err |
|
} |
|
pkgno := digitRegexp.FindAllString(pkg, 1)[0] |
|
ch <- prometheus.MustNewConstMetric(c.cpuPackageThrottle, prometheus.CounterValue, float64(value), pkgno) |
|
} |
|
|
|
return nil |
|
} |
|
|
|
// updateStat reads /proc/stat through procfs and exports cpu related metrics. |
|
func (c *cpuCollector) updateStat(ch chan<- prometheus.Metric) error { |
|
fs, err := procfs.NewFS(*procPath) |
|
if err != nil { |
|
return fmt.Errorf("failed to open procfs: %v", err) |
|
} |
|
stats, err := fs.NewStat() |
|
if err != nil { |
|
return err |
|
} |
|
|
|
for cpuID, cpuStat := range stats.CPU { |
|
cpuName := fmt.Sprintf("cpu%d", cpuID) |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.User, cpuName, "user") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Nice, cpuName, "nice") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.System, cpuName, "system") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Idle, cpuName, "idle") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Iowait, cpuName, "iowait") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.IRQ, cpuName, "irq") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.SoftIRQ, cpuName, "softirq") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Steal, cpuName, "steal") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Guest, cpuName, "guest") |
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.GuestNice, cpuName, "guest_nice") |
|
} |
|
|
|
return nil |
|
}
|
|
|