{ prometheusAlerts+:: { groups+: [ { name: 'node-exporter', rules: [ { alert: 'NodeFilesystemSpaceFillingUp', expr: ||| ( node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceFillingUpWarningThreshold)d and predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[%(fsSpaceFillingUpPredictionWindow)s], 24*60*60) < 0 and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '1h', labels: { severity: 'warning', }, annotations: { summary: 'Filesystem is predicted to run out of space within the next 24 hours.', description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up.', }, }, { alert: 'NodeFilesystemSpaceFillingUp', expr: ||| ( node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceFillingUpCriticalThreshold)d and predict_linear(node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 4*60*60) < 0 and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '1h', labels: { severity: '%(nodeCriticalSeverity)s' % $._config, }, annotations: { summary: 'Filesystem is predicted to run out of space within the next 4 hours.', description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left and is filling up fast.', }, }, { alert: 'NodeFilesystemAlmostOutOfSpace', expr: ||| ( node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceAvailableWarningThreshold)d and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '30m', labels: { severity: 'warning', }, annotations: { summary: 'Filesystem has less than %(fsSpaceAvailableWarningThreshold)d%% space left.' % $._config, description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.', }, }, { alert: 'NodeFilesystemAlmostOutOfSpace', expr: ||| ( node_filesystem_avail_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_size_bytes{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < %(fsSpaceAvailableCriticalThreshold)d and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '30m', labels: { severity: '%(nodeCriticalSeverity)s' % $._config, }, annotations: { summary: 'Filesystem has less than %(fsSpaceAvailableCriticalThreshold)d%% space left.' % $._config, description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available space left.', }, }, { alert: 'NodeFilesystemFilesFillingUp', expr: ||| ( node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 40 and predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 24*60*60) < 0 and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '1h', labels: { severity: 'warning', }, annotations: { summary: 'Filesystem is predicted to run out of inodes within the next 24 hours.', description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up.', }, }, { alert: 'NodeFilesystemFilesFillingUp', expr: ||| ( node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 20 and predict_linear(node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s}[6h], 4*60*60) < 0 and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '1h', labels: { severity: '%(nodeCriticalSeverity)s' % $._config, }, annotations: { summary: 'Filesystem is predicted to run out of inodes within the next 4 hours.', description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left and is filling up fast.', }, }, { alert: 'NodeFilesystemAlmostOutOfFiles', expr: ||| ( node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 5 and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '1h', labels: { severity: 'warning', }, annotations: { summary: 'Filesystem has less than 5% inodes left.', description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.', }, }, { alert: 'NodeFilesystemAlmostOutOfFiles', expr: ||| ( node_filesystem_files_free{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} / node_filesystem_files{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} * 100 < 3 and node_filesystem_readonly{%(nodeExporterSelector)s,%(fsSelector)s,%(fsMountpointSelector)s} == 0 ) ||| % $._config, 'for': '1h', labels: { severity: '%(nodeCriticalSeverity)s' % $._config, }, annotations: { summary: 'Filesystem has less than 3% inodes left.', description: 'Filesystem on {{ $labels.device }}, mounted on {{ $labels.mountpoint }}, at {{ $labels.instance }} has only {{ printf "%.2f" $value }}% available inodes left.', }, }, { alert: 'NodeNetworkReceiveErrs', expr: ||| rate(node_network_receive_errs_total{%(nodeExporterSelector)s}[2m]) / rate(node_network_receive_packets_total{%(nodeExporterSelector)s}[2m]) > 0.01 ||| % $._config, 'for': '1h', labels: { severity: 'warning', }, annotations: { summary: 'Network interface is reporting many receive errors.', description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last two minutes.', }, }, { alert: 'NodeNetworkTransmitErrs', expr: ||| rate(node_network_transmit_errs_total{%(nodeExporterSelector)s}[2m]) / rate(node_network_transmit_packets_total{%(nodeExporterSelector)s}[2m]) > 0.01 ||| % $._config, 'for': '1h', labels: { severity: 'warning', }, annotations: { summary: 'Network interface is reporting many transmit errors.', description: '{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} transmit errors in the last two minutes.', }, }, { alert: 'NodeHighNumberConntrackEntriesUsed', expr: ||| (node_nf_conntrack_entries{%(nodeExporterSelector)s} / node_nf_conntrack_entries_limit) > 0.75 ||| % $._config, annotations: { summary: 'Number of conntrack are getting close to the limit.', description: '{{ $value | humanizePercentage }} of conntrack entries are used.', }, labels: { severity: 'warning', }, }, { alert: 'NodeTextFileCollectorScrapeError', expr: ||| node_textfile_scrape_error{%(nodeExporterSelector)s} == 1 ||| % $._config, annotations: { summary: 'Node Exporter text file collector failed to scrape.', description: 'Node Exporter text file collector on {{ $labels.instance }} failed to scrape.', }, labels: { severity: 'warning', }, }, { alert: 'NodeClockSkewDetected', expr: ||| ( node_timex_offset_seconds{%(nodeExporterSelector)s} > 0.05 and deriv(node_timex_offset_seconds{%(nodeExporterSelector)s}[5m]) >= 0 ) or ( node_timex_offset_seconds{%(nodeExporterSelector)s} < -0.05 and deriv(node_timex_offset_seconds{%(nodeExporterSelector)s}[5m]) <= 0 ) ||| % $._config, 'for': '10m', labels: { severity: 'warning', }, annotations: { summary: 'Clock skew detected.', description: 'Clock at {{ $labels.instance }} is out of sync by more than 0.05s. Ensure NTP is configured correctly on this host.', }, }, { alert: 'NodeClockNotSynchronising', expr: ||| min_over_time(node_timex_sync_status{%(nodeExporterSelector)s}[5m]) == 0 and node_timex_maxerror_seconds{%(nodeExporterSelector)s} >= 16 ||| % $._config, 'for': '10m', labels: { severity: 'warning', }, annotations: { summary: 'Clock not synchronising.', description: 'Clock at {{ $labels.instance }} is not synchronising. Ensure NTP is configured on this host.', }, }, { alert: 'NodeRAIDDegraded', expr: ||| node_md_disks_required{%(nodeExporterSelector)s,%(diskDeviceSelector)s} - ignoring (state) (node_md_disks{state="active",%(nodeExporterSelector)s,%(diskDeviceSelector)s}) > 0 ||| % $._config, 'for': '15m', labels: { severity: 'critical', }, annotations: { summary: 'RAID Array is degraded.', description: "RAID array '{{ $labels.device }}' at {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.", }, }, { alert: 'NodeRAIDDiskFailure', expr: ||| node_md_disks{state="failed",%(nodeExporterSelector)s,%(diskDeviceSelector)s} > 0 ||| % $._config, labels: { severity: 'warning', }, annotations: { summary: 'Failed device in RAID array.', description: "At least one device in RAID array at {{ $labels.instance }} failed. Array '{{ $labels.device }}' needs attention and possibly a disk swap.", }, }, { alert: 'NodeFileDescriptorLimit', expr: ||| ( node_filefd_allocated{%(nodeExporterSelector)s} * 100 / node_filefd_maximum{%(nodeExporterSelector)s} > 70 ) ||| % $._config, 'for': '15m', labels: { severity: 'warning', }, annotations: { summary: 'Kernel is predicted to exhaust file descriptors limit soon.', description: 'File descriptors limit at {{ $labels.instance }} is currently at {{ printf "%.2f" $value }}%.', }, }, { alert: 'NodeFileDescriptorLimit', expr: ||| ( node_filefd_allocated{%(nodeExporterSelector)s} * 100 / node_filefd_maximum{%(nodeExporterSelector)s} > 90 ) ||| % $._config, 'for': '15m', labels: { severity: 'critical', }, annotations: { summary: 'Kernel is predicted to exhaust file descriptors limit soon.', description: 'File descriptors limit at {{ $labels.instance }} is currently at {{ printf "%.2f" $value }}%.', }, }, { alert: 'NodeCPUHighUsage', expr: ||| sum without(mode) (avg without (cpu) (rate(node_cpu_seconds_total{%(nodeExporterSelector)s, mode!="idle"}[2m]))) * 100 > %(cpuHighUsageThreshold)d ||| % $._config, 'for': '15m', labels: { severity: 'info', }, annotations: { summary: 'High CPU usage.', description: ||| CPU usage at {{ $labels.instance }} has been above %(cpuHighUsageThreshold)d%% for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}%%. ||| % $._config, }, }, { alert: 'NodeSystemSaturation', expr: ||| node_load1{%(nodeExporterSelector)s} / count without (cpu, mode) (node_cpu_seconds_total{%(nodeExporterSelector)s, mode="idle"}) > %(systemSaturationPerCoreThreshold)d ||| % $._config, 'for': '15m', labels: { severity: 'warning', }, annotations: { summary: 'System saturated, load per core is very high.', description: ||| System load per core at {{ $labels.instance }} has been above %(systemSaturationPerCoreThreshold)d for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}. This might indicate this instance resources saturation and can cause it becoming unresponsive. ||| % $._config, }, }, { alert: 'NodeMemoryMajorPagesFaults', expr: ||| rate(node_vmstat_pgmajfault{%(nodeExporterSelector)s}[5m]) > %(memoryMajorPagesFaultsThreshold)d ||| % $._config, 'for': '15m', labels: { severity: 'warning', }, annotations: { summary: 'Memory major page faults are occurring at very high rate.', description: ||| Memory major pages are occurring at very high rate at {{ $labels.instance }}, %(memoryMajorPagesFaultsThreshold)d major page faults per second for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}. Please check that there is enough memory available at this instance. ||| % $._config, }, }, { alert: 'NodeMemoryHighUtilization', expr: ||| 100 - (node_memory_MemAvailable_bytes{%(nodeExporterSelector)s} / node_memory_MemTotal_bytes{%(nodeExporterSelector)s} * 100) > %(memoryHighUtilizationThreshold)d ||| % $._config, 'for': '15m', labels: { severity: 'warning', }, annotations: { summary: 'Host is running out of memory.', description: ||| Memory is filling up at {{ $labels.instance }}, has been above %(memoryHighUtilizationThreshold)d%% for the last 15 minutes, is currently at {{ printf "%%.2f" $value }}%%. ||| % $._config, }, }, { alert: 'NodeDiskIOSaturation', expr: ||| rate(node_disk_io_time_weighted_seconds_total{%(nodeExporterSelector)s, %(diskDeviceSelector)s}[5m]) > %(diskIOSaturationThreshold)d ||| % $._config, 'for': '30m', labels: { severity: 'warning', }, annotations: { summary: 'Disk IO queue is high.', description: ||| Disk IO queue (aqu-sq) is high on {{ $labels.device }} at {{ $labels.instance }}, has been above %(diskIOSaturationThreshold)d for the last 30 minutes, is currently at {{ printf "%%.2f" $value }}. This symptom might indicate disk saturation. ||| % $._config, }, }, { alert: 'NodeSystemdServiceFailed', expr: ||| node_systemd_unit_state{%(nodeExporterSelector)s, state="failed"} == 1 ||| % $._config, 'for': '5m', labels: { severity: 'warning', }, annotations: { summary: 'Systemd service has entered failed state.', description: 'Systemd service {{ $labels.name }} has entered failed state at {{ $labels.instance }}', }, }, { alert: 'NodeBondingDegraded', expr: ||| (node_bonding_slaves - node_bonding_active) != 0 ||| % $._config, 'for': '5m', labels: { severity: 'warning', }, annotations: { summary: 'Bonding interface is degraded', description: 'Bonding interface {{ $labels.master }} on {{ $labels.instance }} is in degraded state due to one or more slave failures.', }, }, ], }, ], }, }