Instead of doing the whole metric exposition in a platform specific collector implementation, this creates and updates the metrics in meminfo.go and expected a platform specific implementation of getMemInfo on *meminfoCollector.pull/387/head
parent
269ee7a7b4
commit
2983c4a31d
@ -0,0 +1,60 @@
|
|||||||
|
// Copyright 2015 The Prometheus Authors
|
||||||
|
// Licensed under the Apache License, Version 2.0 (the "License");
|
||||||
|
// you may not use this file except in compliance with the License.
|
||||||
|
// You may obtain a copy of the License at
|
||||||
|
//
|
||||||
|
// http://www.apache.org/licenses/LICENSE-2.0
|
||||||
|
//
|
||||||
|
// Unless required by applicable law or agreed to in writing, software
|
||||||
|
// distributed under the License is distributed on an "AS IS" BASIS,
|
||||||
|
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
||||||
|
// See the License for the specific language governing permissions and
|
||||||
|
// limitations under the License.
|
||||||
|
|
||||||
|
// +build !nomeminfo
|
||||||
|
|
||||||
|
package collector
|
||||||
|
|
||||||
|
import (
|
||||||
|
"fmt"
|
||||||
|
|
||||||
|
"github.com/prometheus/client_golang/prometheus"
|
||||||
|
"github.com/prometheus/common/log"
|
||||||
|
)
|
||||||
|
|
||||||
|
const (
|
||||||
|
memInfoSubsystem = "memory"
|
||||||
|
)
|
||||||
|
|
||||||
|
type meminfoCollector struct{}
|
||||||
|
|
||||||
|
func init() {
|
||||||
|
Factories["meminfo"] = NewMeminfoCollector
|
||||||
|
}
|
||||||
|
|
||||||
|
// Takes a prometheus registry and returns a new Collector exposing
|
||||||
|
// memory stats.
|
||||||
|
func NewMeminfoCollector() (Collector, error) {
|
||||||
|
return &meminfoCollector{}, nil
|
||||||
|
}
|
||||||
|
|
||||||
|
// Update calls (*meminfoCollector).getMemInfo to get the platform specific
|
||||||
|
// memory metrics.
|
||||||
|
func (c *meminfoCollector) Update(ch chan<- prometheus.Metric) (err error) {
|
||||||
|
memInfo, err := c.getMemInfo()
|
||||||
|
if err != nil {
|
||||||
|
return fmt.Errorf("couldn't get meminfo: %s", err)
|
||||||
|
}
|
||||||
|
log.Debugf("Set node_mem: %#v", memInfo)
|
||||||
|
for k, v := range memInfo {
|
||||||
|
ch <- prometheus.MustNewConstMetric(
|
||||||
|
prometheus.NewDesc(
|
||||||
|
prometheus.BuildFQName(Namespace, memInfoSubsystem, k),
|
||||||
|
fmt.Sprintf("Memory information field %s.", k),
|
||||||
|
nil, nil,
|
||||||
|
),
|
||||||
|
prometheus.GaugeValue, v,
|
||||||
|
)
|
||||||
|
}
|
||||||
|
return nil
|
||||||
|
}
|