A lot of packages use StringSet, but they don't use anything else from
the util package. Moving StringSet into another package will shrink
their dependency trees significantly.
If stdin is noninteractive, the io.Copy from stdin to remoteStdin will
unblock when it finishes reading from stdin. In this case, make sure to
close remoteStdin so the server knows the client won't be sending any
more data. This ensures that the remote process terminates. For example:
echo foo | kubectl exec -i <pod> -- cat
Without this change, the `cat` process never terminates and `kubectl
exec` hangs.
Fix interactive exec sessions hanging after you type 'exit'.
Add e2e test to cover noninteractive stdin: `echo a | kubectl exec -i <pod>
cat`
Add e2e test to cover psuedo-interactive stdin: `kubectl exec -i <pod> bash`
Prep for sending multiple data frames over multiple streams in remote command
test, which is more likely to find flakes (requires bump of spdystream
once an issue with the frame worker queues not being fully drained when
a goaway frame is received).
Use iptables --wait (if available) to avoid race conditions with
util.iptables failing if it tries to modify the tables at the same
time as another process.
Also, reorganize the code a bit in preparation for checking for
another flag as well. And, if semver.NewVersion() returns an error, it
means there's a bug in the code somewhere (we should only ever be
passing it valid version strings), so just log that error rather than
returning it to the caller.
The GCE PD plugin uses safe_format_and_mount found on standard GCE images:
https://github.com/GoogleCloudPlatform/compute-image-packages/blob/master/google-startup-scripts/usr/share/google/safe_format_and_mount
On custom images where this is not available pods fail to format and
mount GCE PDs. This patch uses linux utilities in a similar way to the
safe_format_and_mount script to format and mount the GCE PD and AWS EBC
devices. That is first attempt a mount. If mount fails try to use file to
investigate the device. If 'file' fails to get any information about
the device and simply returns "data" then assume the device is not
formatted and format it and attempt to mount it again.
Signed-off-by: Sami Wagiaalla <swagiaal@redhat.com>
The API server will refuse to start if a link-local IP address is selected, however, ChooseNetworkInterface can still select link-local network routes. This causes a startup failure on platforms like DigitalOcean that use a link-local route to fetch metadata.
Signed-off-by: Christian Stewart <christian@paral.in>