This PR adds iSCSI initiatorname parameter to ISCSIVolumeSource
to enable automatic configuration of initiator name per volume.
This would allow for more fine grained configuration, and remove
the need to configure the initiator name on the host by
administrator.
fixes: #47311
If iscsiTransport is not tcp, iSCSI plugin tries to
find devicepath using filepath.Glob but never updates
devicepath with the filepath.Glob result.
This patch fixes the problem.
Fixes#47253
When using iscsi storage with multiple target portal (TP)
addresses and multipathing the volume manager logs on to
the IQN for all portal addresses, but when a pod gets
destroyed the volume manager only logs out for the primary
TP and sessions for another TPs are always remained.
This patch adds methods to store and load iscsi disk
configrations, then uses the stored config at DetachDisk
path.
Fix#45394
This enables use of software or hardware transports viz. be2iscsi,
bnx2i, cxgb3i, cxgb4i, qla4xx, iser and ocs. The default transport
(tcp) happens to be called "default".
Use of non-default transports changes the disk path to the following format:
/dev/disk/by-path/pci-<pci_id>-ip-<portal>-iscsi-<iqn>-lun-<lun_id>